Insertion Flowmeter HydrINS
The HydrINS’s EM Insertion Pipe Flowmeter uses advanced processing
techniques with on board micro-controller which enables a wide variety
of sampling regimes to be set, including signal quality, to suit a wide
variety of applications (tanks, pumping, drinking water network, raw
water)
- Ease of installation with hot-tap capability. Submersible
transmitter
- Internal battery (over 2½ years life) and external DC power
- User selected serial data and two pulse outputs
- Ease of use with external loggers or SCADA systems
- same unit on a wide range of pipe sizes with a very high
accuracy
- Interfaced with Winfluid
Download the datasheet |
|
|

|
|
Transit time flowmeter ChronoFLO
HYDREKA’s range of Transit
Time Ultrasonic Flowmeters use advanced complete coded signal digital
correlation processing techniques to achieve stable measurements even in
difficult conditions
- High accuracy on
drinking water and effluents applications
- No need for zero
adjustment
- External inputs
for thermal energy and external flowmeter logging applications
- External outputs
for process control
- Available in portable version with 2 months
of battery life and in externally powered version
- Interfaced with Winfluid
Download the datasheet |
|
 |
|
SoundSens®
Multi-point correlation system
SoundSens is a unique leak localization system combining sound logging
and correlation into one simple to use, cost effective process.
-
Three or more SoundSens Correlator Pods used together can find leaks in
complex interconnected pipe networks where traditional correlators
cannot resolve the exact position.
- Cross correlation with several correlator pods
- Provides
clean signals even in difficult applications.
- Can
be used on various pipe materials including Cast Iron, Cement and
Plastic over relatively long distances
Download
the datasheet |
|
|

|
|
Portable refrigerated sampler with 24 bottles
This Hydreka's sampler is the first portable refrigerated sampler
with 24 bottles (1L or 500 ml). Formed by a refrigerated group adjusted
at +4°C and a sampler (peristaltic pump) according to the ISO 56 67-10
standard.
The freezing group and the sampler are powered either by battery or
power supply. The refrigerated group is started at the first sampling
and stops only on hand control.
This sampler provides results that you can count on. Samples are
maintained at 4°C, while an advanced sample delivery system assures the
highest sample integrity |
|
 |
|
Portable refrigerated sampler
Portable refrigerated sampler Hydreka is formed by a 17 l polyethylene
bottle or a 18 l glass bottle, by a refrigerated group adjusted at 4°C
and a sampler (peristaltic) according to the ISO 56 67-10 standard.
The freezing group and the sampler are powered either by battery or
power supply. The refrigerated group is started at the first sampling
and stops only on hand control.
The sampler can be a
complete measuring station with a sampler 900PMAX
(flow, pH, conductivity, temperature, sampling), the whole
equipment being interfaced with Winfluid.
|
|
 |
|
HYDREKA's weir stoppers
New range of weirs to measure low flow on sewage networks.
- Easy to fit and take down with the pneumatic joint
- Accurate measurement with the 53°8' angle (french norm) or the
circular section
- Level measurement and height to flow conversion with the S950
bubbler
- Dowloading and data process with Winfluid software.
- Available with four diameters (150, 200, 250 and 300 mm)
|
|